Human IL-1 alpha/IL-1F1 Magnetic Luminex Performance Assay  1 KT图1

Human IL-1 alpha/IL-1F1 Magnetic Luminex Performance Assay 1 KT

2024-11-27 10:14IP属地 广东省东莞市 电信00留言

 

* Antibody-coated beads supplied in compatible Bead Sets, sold separately (see below).

 

Product Features

 

Base Kit Contents

 

Bead Set Contents

 

    Information for Compatiable Analytes

For performance data for the different analyte-specific beads, please see product datasheets for the compatible individual Bead Sets.

AnalyteCatalog
Number
Sensitivity
(pg/mL)
High Standard Value*
(pg/mL)
Microparticle
Region
CXCL5/ENA-78
4.146,90012
FGF basic
4.915,75013
G-CSF
1.484,50014
GM-CSF
1.982,85015
IFN-gamma
1.273,25018
IL-1 alpha/IL-1F1
0.361,85019
IL-1 beta/IL-1F2
0.572,40020
IL-1ra/IL-1F3
10.915,50021
IL-2
2.232,30022
IL-4
4.463,75025
IL-5
0.711,38026
IL-6
1.114,95027
CXCL8/IL-8
1.972,95028
IL-10
0.303,20029
IL-17
1.102,55030
CCL2/MCP-1
0.472,10033
CCL3/MIP-1 alpha
28.3016,50034
CCL4/MIP-1 beta
0.726,20035
CCL5/RANTES
1.912,40036
TNF-alpha
1.504,50037
Tpo
9.9416,60038
VEGF
1.842,85039

*A standard curve must be generated each time an assay is run, utilizing values from the Standard Value Card included in the Base Kit.

 

Validated Samples and Recommended Starting Dilution

AnalyteCell Culture
Supernate
SerumEDTA PlasmaHeparin Plasma
CXCL5/ENA-78None1:41:41:4
FGF basicNone1:41:4N/R
G-CSFNone1:41:41:4
GM-CSFNone1:41:41:4
IFN-gammaNone1:41:41:4
IL-1 alpha/IL-1F1None1:41:41:4
IL-1 beta/IL-1F2None1:41:41:4
IL-1ra/IL-1F3None1:41:41:4
IL-2None1:41:41:4
IL-4None1:41:41:4
IL-5None1:41:41:4
IL-6None1:41:41:4
CXCL8/IL-8None1:41:41:4
IL-10None1:41:41:4
IL-17None1:41:41:4
CCL2/MCP-1None1:41:41:4
CCL3/MIP-1 alphaNone1:41:41:4
CCL4/MIP-1 betaNone1:41:41:4
CCL5/RANTESNone1:1001:1001:100
TNF-alphaNone1:41:41:4
TpoNone1:41:41:4
VEGFNone1:41:41:4

N/R=This sample type is not recommended for use in this assay

 

More Information about Magnetic Bead-Based Multiple Kits for the Luminex Platform

Magnetic  multiplex kits are designed for use with the  CCD Imager. Alternatively, kits can be used with the  or Bio-Rad® Bio-Plex®, dual laser, flow-based sorting and detection platforms.

Analyte-specific antibodies are pre-coated onto color-coded magnetic microparticles. Microparticles, standards and samples are pipetted into wells and the immobilized antibodies bind the analytes of interest. After washing away any unbound substances, a biotinylated antibody cocktail specific to the analytes of interest is added to each well. Following a wash to remove any unbound biotinylated antibody, streptavidin-phycoerythrin conjugate (Streptavidin-PE), which binds to the biotinylated antibody, is added to each well. A final wash removes unbound Streptavidin-PE, the microparticles are resuspended in buffer and read using the Luminex MAGPIX Analyzer. A magnet in the analyzer captures and holds the superparamagnetic microparticles in a monolayer. Two spectrally distinct Light Emitting Diodes (LEDs) illuminate the beads. One LED identifies the analyte that is being detected and the second LED determines the magnitude of the PE-derived signal, which is in direct proportion to the amount of analyte bound. Each well is imaged with a CCD camera. Kits can also be used with Luminex 100/200 or a Bio-Rad Bio-Plex dual laser, flow-based systems.

Trademarks and registered trademarks are the property of their respective company.

举报
收藏 0
评论 0
联系方式